What to pay attention to when installing industrial washing machines

1. Inspection before installation

Before installing the industrial washing machine, be sure to check whether it is damaged during transportation. Make sure that all connecting bolts, pipelines and pipe joints (intake pipe, water inlet pipe, drain pipe), all electrical joints, and plug-ins are loose. Check the industrial Whether the dampers and damping springs of the washing machine are damaged, if found, please deal with them immediately to prevent accidents.


2. Industrial washing machine installation

When installing an industrial washing machine, pay attention to the size of the surrounding clearance space. There must be enough space between the industrial washing machine and the wall to facilitate future daily repairs and maintenance. The rear side of the industrial washing machine should not be less than 0.8 meters from the wall, and the sides should not be less than 0.8 meters, and it must be installed on a solid foundation.


3. Adjustment level of industrial washing machines

In order to reduce the vibration and noise during high-speed dehydration, please fix the industrial washing machine firmly on the foundation. Once the industrial washing machine is not calibrated, it may cause the industrial washing machine to shake violently and cause accidents during high-speed dehydration. Therefore, the industrial washing machine must be The four anchor bolts are relatively horizontal, and then tighten the anchor bolts to make the industrial washing machine firmly fixed on the foundation.


Fourth, the entry of steam source

The steam inlet of the industrial washing machine is at the upper part of the washing machine. Normally, the working steam pressure is between 0.4PA and 0.6PA. If the steam pressure is higher than 0.85PA, the steam pipeline may be damaged, causing personal injury and death. A manual shut-off valve, filter and pressure reducing valve should be installed between the washing machine and the washing machine in order to adjust the steam pressure of the industrial washing machine. All pipes must be insulated. It is forbidden to touch the steam pipe fittings. The pipe surface is very hot, which will cause For severe burns, if you want to touch the pipeline for maintenance, please turn off the steam and wait for it to cool down before operating.


5. Entry of water and air

1. Cold water:

The cold water inlet connector for cold water entering the industrial washing machine is a Φ50mm pipe located on the upper left side of the back of the industrial washing machine. The water pressure is (2-6kg/mm2). If the water pressure is lower than the requirement, the water inlet time will be extended; when the water pressure is higher than At 6.8kg/cm, because the water pressure is too high, the pipeline may be damaged and personnel may be injured, so a manual shut-off valve and filter valve must be installed between the industrial washing machine and the water inlet pipe.


2. Hot water:

The situation of hot water is basically similar to that of cold water, and a manual shut-off valve is also required. It is worth noting that the temperature of the hot water should not be too high to prevent damage to the clothes.


3. Compressed air:

The industrial washing machine and the air compressor are connected by a Φ8mm nylon air pipe. The industrial washing machine has a triple air source, so it is best to adjust the pressure to 4kg/mm2, and to keep the air pressure between 5.4-6.7kg/cm2, Too big or too small will cause problems.


4. Drain outlet:

There is a drain port under the industrial washing machine. Connected to the drain port is a high-temperature resistant Φ114mm plastic pipe. The drain pipe must be higher than the ground. Please do not put the nozzle in the water, otherwise it will cause the drain pipe to drain. The drainage port must have a flow rate of 300 liters per minute, otherwise it will cause overflow, which will not only stain the clothes, but also make the industrial washing machine unable to dehydrate.